{"id":175462,"date":"2025-05-29T13:05:13","date_gmt":"2025-05-29T10:05:13","guid":{"rendered":"https:\/\/alphadynamic.eu\/?page_id=175462"},"modified":"2025-06-28T14:34:05","modified_gmt":"2025-06-28T11:34:05","slug":"nayara-peristaltic-pump","status":"publish","type":"page","link":"https:\/\/alphadynamic.eu\/en\/products\/nayara-peristaltic-pump\/","title":{"rendered":"NAYARA Peristaltic Pump"},"content":{"rendered":"<p>[vc_row el_id=&#8221;pageTitle&#8221; el_class=&#8221;productTitle&#8221;][vc_column][vc_custom_heading source=&#8221;post_title&#8221; font_container=&#8221;tag:h1|font_size:24px|text_align:left|color:%23ed1c24|line_height:34px&#8221; use_theme_fonts=&#8221;yes&#8221;][\/vc_column][\/vc_row][vc_row el_id=&#8221;productFinalTabs&#8221;][vc_column][vc_tta_tabs style=&#8221;outline&#8221; shape=&#8221;square&#8221; color=&#8221;white&#8221; spacing=&#8221;10&#8243; gap=&#8221;5&#8243; active_section=&#8221;1&#8243; no_fill_content_area=&#8221;true&#8221;][vc_tta_section title=&#8221;NAYARA PRODUCTS&#8221; tab_id=&#8221;1636545761239-2ec5e7dd-3249&#8243;][vc_basic_grid post_type=&#8221;ids&#8221; item=&#8221;339&#8243; grid_id=&#8221;vc_gid:1751110265551-185184fd-9d92-9&#8243; include=&#8221;175487, 175475&#8243;][\/vc_tta_section][vc_tta_section title=&#8221;TECHNICAL DATA&#8221; tab_id=&#8221;techical-data5339-dbb9&#8243; el_class=&#8221;tab1&#8243;][vc_row_inner][vc_column_inner][\/vc_column_inner][\/vc_row_inner][vc_column_text]<span style=\"font-size: 12pt;\"><strong>ADPV SHOE TECHNOLOGY<\/strong><\/span><\/p>\n<table style=\"width: 36.6268%;\" width=\"325\">\n<tbody>\n<tr>\n<td style=\"width: 51.0903%;\" width=\"170\">Pump Body<\/td>\n<td style=\"width: 61.8422%;\" width=\"155\">: Ductile Cast Iron<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Maximum Presure<\/td>\n<td style=\"width: 61.8422%;\">: 15 bar<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">\u039caximum Capacity<\/td>\n<td style=\"width: 61.8422%;\">: 80 m3\/h<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Maximum Temperature<\/td>\n<td style=\"width: 61.8422%;\">: 80<sup>o<\/sup>C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Achievable suction<\/td>\n<td style=\"width: 61.8422%;\">: Up to 0,9 Bar<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Available Tubes<\/td>\n<td style=\"width: 61.8422%;\">: NR, NBR, EPDM, VITON<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Suitable for<\/td>\n<td style=\"width: 61.8422%;\">: Continues Operation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][vc_separator border_width=&#8221;4&#8243;][vc_column_text]<span style=\"font-size: 12pt;\"><strong>ADPN ROLLER TECHNOLOGY<\/strong><\/span><\/p>\n<table style=\"width: 36.6268%;\" width=\"325\">\n<tbody>\n<tr>\n<td style=\"width: 51.0903%;\" width=\"170\">Pump Body<\/td>\n<td style=\"width: 61.8422%;\" width=\"155\">:\u00a0 Aluminum<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Maximum Presure<\/td>\n<td style=\"width: 61.8422%;\">: 7 bar<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">\u039caximum Capacity<\/td>\n<td style=\"width: 61.8422%;\">: 9 m3\/h<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Maximum Temperature<\/td>\n<td style=\"width: 61.8422%;\">: 80<sup>o<\/sup>C<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Achievable suction<\/td>\n<td style=\"width: 61.8422%;\">: Up to 0,8 Bar<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Available Tubes<\/td>\n<td style=\"width: 61.8422%;\">: NR, NBR, EPDM<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 51.0903%;\">Suitable for<\/td>\n<td style=\"width: 61.8422%;\">: intemittent Operation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;ADVANTAGES&#8221; tab_id=&#8221;materials5339-dbb9&#8243; el_class=&#8221;tab2&#8243;][vc_column_text]<span style=\"font-family: Times New Roman, serif;\"><span style=\"font-size: medium;\"><span style=\"color: #c00000;\"><span style=\"font-family: Verdana, serif;\"><span style=\"font-size: large;\">Advantages <\/span><\/span><\/span><\/span><\/span><\/p>\n<ul>\n<li>Excellent Performance with abrasive and corrosive liquids<\/li>\n<li>Able to pump large solids<\/li>\n<li>Extremely high suction capabilities<\/li>\n<li>Unlimited dry running<\/li>\n<li>Full dosing control<\/li>\n<li>Robust Construction<\/li>\n<li>Low shear and reversible operation<\/li>\n<li>FDA hoses on request<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":14,"featured_media":178760,"parent":113,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"acf":[],"_links":{"self":[{"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/pages\/175462"}],"collection":[{"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/comments?post=175462"}],"version-history":[{"count":27,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/pages\/175462\/revisions"}],"predecessor-version":[{"id":179622,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/pages\/175462\/revisions\/179622"}],"up":[{"embeddable":true,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/pages\/113"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/media\/178760"}],"wp:attachment":[{"href":"https:\/\/alphadynamic.eu\/en\/wp-json\/wp\/v2\/media?parent=175462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}